MCP9600-I/MX
- Mfr.Part #
- MCP9600-I/MX
- Manufacturer
- Microchip Technology
- Package / Case
- 20-VQFN Exposed Pad
- Datasheet
- Download
- Description
- IC THRMOCPLE TO DIG CONV 20MQFN
- Stock
- 2,495
- In Stock :
- 2,495
Request A Quote(RFQ)
- * Fullname:
- * Company:
- * E-Mail:
- Phone:
- Comment:
- * Quantity:
- Manufacturer :
- Microchip Technology
- Product Category :
- Sensor and Detector Interfaces
- Height Seated (Max) :
- 1mm
- Supply Voltage-Max (Vsup) :
- 5.5 V
- Min Supply Voltage :
- 2.7V
- Mounting Type :
- Surface Mount
- Package Shape :
- Square
- REACH SVHC :
- No SVHC
- Base Product Number :
- MCP9600
- Mount :
- Surface Mount
- Terminal Position :
- QUAD
- Reach Compliance Code :
- Compliant
- Package / Case :
- 20-VQFN Exposed Pad
- Operating Temperature :
- -40°C~85°C
- Surface Mount :
- yes
- Number of Functions :
- 1
- Output Type :
- Digital
- Lead Free :
- Lead Free
- Terminal Pitch :
- 0.65mm
- RoHS :
- Compliant
- Interface :
- I2C
- Supply Voltage :
- 3.3V
- JESD-30 Code :
- S-PQCC-N20
- Schedule B :
- 8542390000
- Seated Height-Max :
- 1 mm
- Length :
- 5mm
- Time@Peak Reflow Temperature-Max (s) :
- 30
- Current - Supply :
- 300μA
- RoHS Status :
- ROHS3 Compliant
- Series :
- --
- Width :
- 5mm
- Input Type :
- Thermocouple
- Manufacturer :
- Microchip Technology Inc
- Factory Lead Time :
- 14 Weeks
- Base Part Number :
- MCP9600
- Product Status :
- Obsolete
- Number of Terminals :
- 20
- Number of Terminations :
- 20
- Number of Pins :
- 20
- Moisture Sensitivity Level (MSL) :
- 3 (168 Hours)
- Screening Level :
- TS 16949
- Package :
- Tube
- Terminal Finish :
- Matte Tin (Sn)
- Operating Supply Current :
- 300μA
- JESD-609 Code :
- e3
- Supply Voltage-Min (Vsup) :
- 2.7 V
- Pbfree Code :
- yes
- Type :
- Thermocouple to Digital Converter
- Max Operating Temperature :
- 85 °C
- Supplier Device Package :
- 20-MQFN (5x5)
- Peak Reflow Temperature (Cel) :
- 260
- Min Operating Temperature :
- -40 °C
- Packaging :
- Tube
- Terminal Form :
- NO LEAD
- Analog IC - Other Type :
- ANALOG CIRCUIT
- Max Supply Voltage :
- 5.5V
- Datasheets
- MCP9600-I/MX

[Sensor and Detector Interfaces Microchip Technology MCP9600-I/MX] Overview
Introducing the cutting-edge MCP9600-I/MX from Microchip Technology, a leading innovator in integrated circuits. This sophisticated IC (integrated circuit) serves as a Thermal Couple to Digital Converter, providing unparalleled accuracy and reliability in temperature sensing applications. Designed with utmost precision and efficiency, the MCP9600-I/MX offers a seamless transition from analog to digital temperature measurements, catering to the diverse needs of industries worldwide.
[MCP9600-I/MX] Features
- High Precision: The MCP9600-I/MX ensures precise temperature measurements with minimal error margins, guaranteeing accuracy in critical operations.
- Compact Design: Housed in a 20MQFN package, this IC optimizes space utilization without compromising on performance, ideal for space-constrained applications.
- Low Power Consumption: With efficient power management capabilities, the MCP9600-I/MX minimizes energy consumption, prolonging battery life in portable devices.
- Wide Temperature Range: From sub-zero temperatures to high heat environments, this IC operates reliably across a broad spectrum, adapting to various industrial settings.
- Robust Interface: Equipped with robust communication interfaces, including I2C and SMBus, the MCP9600-I/MX ensures seamless integration with diverse microcontroller platforms.
- Enhanced Stability: Advanced internal compensation algorithms maintain stability in challenging environmental conditions, delivering consistent performance over time.
[MCP9600-I/MX] Applications
- Industrial Automation: Employ the MCP9600-I/MX in industrial automation systems for precise temperature monitoring in manufacturing processes, ensuring product quality and process efficiency.
- Medical Devices: Utilize the MCP9600-I/MX in medical devices such as thermometers and thermal therapy equipment for accurate temperature measurement and control, enhancing patient care and safety.
- Environmental Monitoring: Incorporate the MCP9600-I/MX into environmental monitoring systems for precise temperature sensing in climate-controlled environments, ensuring optimal conditions in research facilities and greenhouses.
This IC is seamlessly integrated into PLCs (Programmable Logic Controllers) and SCADA (Supervisory Control and Data Acquisition) systems, enabling real-time temperature data acquisition and analysis.
With its high precision and reliability, this IC contributes to the precise monitoring of patient temperature in clinical settings, facilitating accurate diagnosis and treatment.
This IC enables real-time monitoring of temperature fluctuations, allowing proactive adjustments to maintain desired environmental parameters.
You may place an order without registering to Chip IC. We strongly recommend that you log in before purchasing as you can track your order at any time.
RFQ (Request for Quotations)It is recommended to send RFQ to get the latest prices and stock availability about the part.Our sales will reply to your inquiry within 24 hours.
Payment MethodFor your convenience, we accept multiple payment methods in USD, Such as:PayPal, Credit Card, and wire transfer.
IMPORTANT NOTICEYou may place an order without registering to 1. You'll receive an order confirmations by e-mail soon . (Please remember to check the spam box if you didn't hear from us). 2. Since stock availability and prices may change at any time, the sales will reconfirm the order details and update you at soonest time.
Most of our products are shipped via FEDEX,DHL,UPS and SF EXPRESS...
Shipping CostShipping Cost starts at $40, but some countries will exceed $40. For example (South Africa, Brazil, India, Pakistan, Israel, etc.).If customer have shipping account, we can make shipment under customer’s shipping account with freight collect directly.
The basic freight (for package ≤0.5 KG ) depends on the time zones and countries
Once the goods are shipped, estimated delivery time depends on the shipping methods you chose. You can track it by the tracking no.
















