282-638
- Mfr.Part #
- 282-638
- Manufacturer
- WAGO
- Package / Case
- Datasheet
- Download
- Description
- GROUND CONDUCTOR DISCONNECT TERM
- Stock
- 45,793
- In Stock :
- 45,793
Request A Quote(RFQ)
- * Fullname:
- * Company:
- * E-Mail:
- Phone:
- Comment:
- * Quantity:
- Manufacturer :
- WAGO
- Product Category :
- Din Rail, Channel
- Manufacturer :
- Wago
- Voltage - IEC :
- -
- Depth :
- 37
- Color :
- Gray
- Terminal - Width :
- 16.0mm
- No. of rows :
- 2
- Product Status :
- Active
- Pins per row :
- 2
- Industrial packaging :
- yes
- Configuration :
- L
- Number of Positions :
- 4
- Nominal current - rounded value :
- 30A
- Number of Circuits :
- 2
- PPAP :
- No
- Termination Style :
- Push In, Spring
- Packaging :
- Box
- Maximum Operating Temperature (°C) :
- 105
- Cross section (inflexible) (min.) :
- 0.20mm²
- AWG max. :
- 10
- Series :
- 793
- Manufacturer part # :
- 282-638
- Features :
- + test option
- HTS :
- 8536.90.40.00
- Automotive :
- No
- Note :
- n/a
- Height :
- 37mm
- Clamp width :
- 16mm
- Wire Gauge or Range - AWG :
- 10-24 AWG
- Fuse Type :
- -
- RoHS :
- yes
- Minimum Operating Temperature (°C) :
- -60
- Number of Contacts :
- 4
- Nominal voltage :
- 400V
- Connection :
- Pull spring
- Cross section (flexible) (min.) :
- 0.20mm²
- Width :
- 16mm
- Nominal current :
- 30A
- Disconnect Type :
- -
- EU RoHS :
- Compliant with Exemption
- Wire Gauge or Range - mm² :
- 0.2-6mm²
- Housing Color :
- Gray
- Cross section (inflexible) (max.) :
- 6mm²
- Type :
- Ground Terminal Block
- ECCN (US) :
- EAR99
- Mounting Type :
- DIN Rail
- Inflammability class of insulation material according to with UL94 :
- V0
- Dim :
- (W x H) 16 mm x 37 mm
- Number of Levels :
- 1
- Connectable conductor cross section solid-core :
- 0.2 - 6
- Stripping Length :
- 12mm ~ 13mm
- Voltage - UL :
- -
- Material Flammability Rating :
- UL94 V-0
- Mounting :
- DIN Rail
- Connectable conductor cross section fine-strand with cable end sleeve :
- 0.75 - 4
- Package :
- Box
- Stripping length (max.) :
- 13mm
- Connectable conductor cross section multi-wired :
- 0.2 - 6
- Number of Rows :
- 2
- AWG (min.) :
- 24
- Cross section (flexible) (max.) :
- 6mm²
- Rated current In :
- 30
- Connectable conductor cross section fine-strand without cable end sleeve :
- 0.2 - 6
- Content :
- 12pc(s)
- Material - Insulation :
- Polyamide (PA66), Nylon 6/6
- Min. stripping length :
- 12mm
- Termination Method :
- Spring Clamp
- Length :
- 85
- Datasheets
- 282-638

282-638 datasheet pdf and Terminal Blocks - Adapters product details from WAGO stock available at Xinshop
You may place an order without registering to Chip IC. We strongly recommend that you log in before purchasing as you can track your order at any time.
RFQ (Request for Quotations)It is recommended to send RFQ to get the latest prices and stock availability about the part.Our sales will reply to your inquiry within 24 hours.
Payment MethodFor your convenience, we accept multiple payment methods in USD, Such as:PayPal, Credit Card, and wire transfer.
IMPORTANT NOTICEYou may place an order without registering to 1. You'll receive an order confirmations by e-mail soon . (Please remember to check the spam box if you didn't hear from us). 2. Since stock availability and prices may change at any time, the sales will reconfirm the order details and update you at soonest time.
Most of our products are shipped via FEDEX,DHL,UPS and SF EXPRESS...
Shipping CostShipping Cost starts at $40, but some countries will exceed $40. For example (South Africa, Brazil, India, Pakistan, Israel, etc.).If customer have shipping account, we can make shipment under customer’s shipping account with freight collect directly.
The basic freight (for package ≤0.5 KG ) depends on the time zones and countries
Once the goods are shipped, estimated delivery time depends on the shipping methods you chose. You can track it by the tracking no.
Manufacturer related products
Catalog related products
Related products
| Part | Manufacturer | Stock | Description |
|---|---|---|---|
| 282-101 | WAGO | 341 | 2-CONDUCTOR THROUGH TERMINAL BLO |
| 282-104 | WAGO | 63 | 2-CONDUCTOR THROUGH TERMINAL BLO |
| 282-107 | WAGO | 89 | 2-CONDUCTOR GROUND TERMINAL BLOC |
| 282-120 | WAGO | 12,430 | 2-CONDUCTOR FUSE TERMINAL BLOCK; |
| 282-122 | WAGO | 3,600 | 2-CONDUCTOR FUSE TERMINAL BLOCK; |
| 282-124 | WAGO | 42,728 | 2-CONDUCTOR FUSE TERMINAL BLOCK; |
| 282-126 | WAGO | 21,872 | 2-CONDUCTOR FUSE TERMINAL BLOCK; |
| 282-128 | WAGO | 3,960 | 2-CONDUCTOR FUSE TERMINAL BLOCK; |
| 282-128/281-413 | WAGO | 17 | 2-CONDUCTOR FUSE TERMINAL BLOCK; |
| 282-128/281-417 | WAGO | 35,330 | 2-CONDUCTOR FUSE TERMINAL BLOCK; |
| 282-128/281-418 | WAGO | 26,182 | 2-CONDUCTOR FUSE TERMINAL BLOCK; |
| 282-131 | WAGO | 41,776 | 2-CONDUCTOR DISCONNECT/TEST TERM |
| 282-133 | WAGO | 46,869 | 2-CONDUCTOR THROUGH TERMINAL BLO |
| 282-135 | WAGO | 37,904 | 2-CONDUCTOR DISCONNECT/TEST TERM |
| 282-137 | WAGO | 31,631 | LOCK-OUT; PREVENTS RECLOSING OF |